Camsafe is a high-efficiency safety exhaust filter unit for ducts. Features fully welded housing tested at 5000Pa for airtightness. High-flatness sealing surface with filter gasket ensures leak-free performance. H14 filter meets ≥99.99% PAO/DEHS efficiency. Housing options: 304 stainless steel or ca
Product Introduction
Camsafe is a high-efficiency safety exhaust filter unit installed in ductwork. It can be equipped with a safety bag for filter replacement. The main housing structure is fully welded and undergoes structural strength and airtightness testing at 5000Pa to ensure that hazardous gases in the duct do not leak. The high-flatness sealing surface inside the housing, combined with the filter gasket, achieves leak-free performance between the filter upstream and downstream. When equipped with an H14 filter, it meets the standard requirement of PAO/DEHS total efficiency not less than 99.99%. The housing is made of 304 stainless steel, with carbon steel epoxy spray coating also available.
Product Features
Camsafe is welded firmly without deformation, ensuring overall structural strength and airtightness of the housing
Housing made of 3mm thick stainless steel 304 or cold-rolled steel; stainless steel surface passivated, cold-rolled steel surface epoxy spray coated in color RAL9016, ensuring the housing surface is not prone to dust accumulation and resistant to corrosion from formaldehyde and H₂O₂
Filter clamping device made of stainless steel 304 for quick clamping
Inlet/outlet square flanges, pre-drilled before delivery, flange width 50mm
Safety replacement bag ensures operators do not come into contact with the filter
Camsafe compatible filters: Camsafe-1000 filter size 610×610×292mm; Camsafe-450 filter size 305×610×292mm
Double glass window panes provide critical thermal, acoustic, and particulate isolation. The sealed argon or krypton fill minimizes convective currents at the viewport—preventing localized turbulence that could disturb laminar flow. Conductive coatings enable static dissipation, while laminated construction meets impact and fire-rating requirements. In practice, they reduce particle ingress through observation points by >90% versus single-pane alternatives and support stable differential pressures across ISO Class 3/4 boundaries.
Semiconductor production lines (particle-sensitive), biomedical research labs, pharmaceutical manufacturing, and any controlled environment requiring precise airflow, velocity, and noise level control.
An FFU is a modular air purification device combining a fan with HEPA or ULPA filters in a single housing. It provides localized clean air supply and is fundamental to cleanroom contamination control.
A Clean Booth provides a localized clean environment within a larger room. It utilizes a cleanroom Fan Filter Unit(FFU) to maintain positive pressure and filter airborne particles. This type of cleanroom Local Clean Equipment is essential for processes requiring ISO Class 5 or better conditions without constructing a full cleanroom. Installation is flexible and cost-effective for specific workstations needing contamination control.
Personnel entry requires strict decontamination. A cleanroom Single-Person Air Shower Room is designed for individual access, while a cleanroom Multi-Person Air Shower Room handles higher traffic volumes. The general cleanroom Air Shower Room uses high-velocity air to remove particles from clothing before entering critical zones. Proper interlocking systems ensure doors do not open simultaneously, maintaining pressure differentials and cleanliness standards effectively.
Large items require specialized decontamination channels. A cleanroom Cargo Air Shower Room accommodates pallets and large equipment entering the facility. Continuous flow is managed via a cleanroom Goods Air Shower Tunnel for high-volume logistics. Smaller items pass through a cleanroom Aluminum Pass Box which offers durability and corrosion resistance. These systems prevent external contaminants from compromising the internal environment during material transport operations.
Air distribution determines cleanliness levels. The cleanroom Air Supply Device regulates volume and pressure within the space. Filtrated air is dispersed through a cleanroom High Efficiency Air Outlet to ensure uniform coverage without turbulence. Modular setups often utilize a cleanroom Clean Panel Clean Booth to integrate these components seamlessly. Proper design ensures consistent air changes per hour to meet regulatory compliance standards.
Classification depends on air cleanliness levels. A Clean Booth provides localized ISO Class 5 environments. Integration with a cleanroom Fan Filter Unit(FFU) ensures consistent airflow. Regular maintenance of the cleanroom High Efficiency Air Outlet is crucial for sustaining particulate control standards within the workspace.
Personnel entry requires strict decontamination. A cleanroom Single-Person Air Shower Room removes particles from suits before entry. For larger groups, a cleanroom Multi-Person Air Shower Room increases throughput efficiently. Cargo transport utilizes a cleanroom Cargo Air Shower Room to prevent external contaminants from entering critical production zones during material transfer.
Maintaining proper airflow is critical for contamination control. The cleanroom Fan Filter Unit(FFU) ensures uniform distribution across the workspace. Integration with a cleanroom Clean Booth provides a localized ISO Class 5 environment. Additionally, installing a cleanroom High Efficiency Air Outlet helps manage exhaust and pressure differentials effectively. Regular filter checks are necessary to sustain performance standards without compromising operational integrity.